CLBFV - ROYCO 560

Product Identification

Product ID:ROYCO 560
MSDS Date:10/17/2000
FSC:9150
NIIN:01-439-0756
Status Code:A
MSDS Number: CLBFV

Responsible Party
ROYAL LUBRICANTS COMPANY INC.
MERRY LN
EAST HANOVER, NJ 07936-0518
US

Emergency Phone: 973-887-7411

Info Phone: 201-887-7411

Preparer: PRODUCT SAFETY

Cage: 07950

Contractor
ROYAL LUBRICANTS COMPANY INC.
518 EAST HANOVER, NJ 07936 US

Telephone: 973-887-7411/7410

Cage: 07950

Ingredients

SYNTHETIC ESTER

CAS: 67762-53-2


SYNTHETIC ESTER

CAS: 67762-52-1


OCTYLATED N-PHENYL-1-NAPHTHYLAMINE

CAS: 68259-36-9


P,P'-DIOCTYLDIPHENYLAMINE

CAS: 68411-46-1


TRICRESYL PHOSPHATE (MIXED ISOMERS)

CAS: 1330-78-5

RTECS: TD0175000


MINOR ADDITIVES (MIXTURE)

Hazards

LD50 LC50 Mixture:NOT AVAILABLE
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYE: MILDLY IRRITATING. SKINI: MILDLY
IRRITATING. PROLONGED/REPEATED CONTACT MAY RESULT IN ABSORPTION OF
TRICRESYL PHOSPHATE WHICH COULD LEAD TO DELAYED NEUROTOXICITY.
RELEASE DURING HIGH PRESSURE MA Y RESULT IN INJECTION OF OIL INTO
SKIN CAUSING LOCAL NECROSIS. INHALATION: MILDLY IRRITATING TO THE
NOSE, THROAT, & RESPIRATORY TRACT. COULD LEAD TO NEUROTOXICITY.
INGESTION: COULD BE TOXIC IF SWALL OWED, RESULTING IN DELAYED
NEUROTOXICITY.
Explanation of Carcinogenicity:THIS PRODUCT DOES NOT CONTAIN ANY
CARCINOGENS AS IDENTIFIED BY IARC, NTP, OR OSHA.
Effects of Overexposure:IRRITATION AS NOTED IN HEALTH HAZARD. DELAYED
NEUROTOXICITY MAY BE EVIDENCED BY NUMBNESS AND TINGLING OF THE
HANDS AND FEET, WEAKNESS AND CRAMPS, AND UNSTEADY GAIT. LOCAL
NEGROSIS IS EVIDENCED BY DELA YED ONSET OF PAIN AND TISSUE DAMAGE A
FEW HOURS FOLLOWING INJECTION.
Medical Cond Aggravated by Exposure:PREEXISTING EYE, SKIN, RESPIRATORY
AND NERVE DISORDERS MAY BE AGGRAVATED BY EXPOSURE TO THIS PRODUCT.

First Aid

First Aid:EYE: FLUSH WITH PLENTY OF WATER FOR 15 MIN. WHILE HOLDING
EYELIDS OPEN. SKIN: REMOVE CONTAIMINATED CLOTHING/SHOES & WIPE
EXCESS FROM SKIN. FLUSH WITH WATER. IF MATERIAL IS INJECTED UNDER
THE SKIN, SE EK PROMPT MEDICAL ATTENTION. INHALATION: REMOVE
VICTIM TO FRESH AIR & PROVIDE OXYGEN IF BREATHING IS DIFFICULT.
INGESTION: DO NOT GIVE LIQUIDS IF VICTIM IS UNCONSCIOUS OR VERY
DROWSY. OTHERWISE, GIV E NO MORE THAN 2 GLASSES OF WATER & INDUCE
VOMITING BY GIVING 30 CC (2 TABLESPOONS) SYRUP OF IPECAC OR BY
TOUCHING THE BACK OF VICTIM'S THROAT. GET MEDICAL ATTENTION IN ALL
CASES OF EXPOSURE.

Fire Fighting

Flash Point Method:COC
Flash Point:=260.C, 500.F
Lower Limits:N/AV
Upper Limits:N/AV
Extinguishing Media:USE WATER FOG, FOAM, DRY CHEMICAL OR CO2, DO NOT
USE A DIRECT STREAM OF WATER. PRODUCT WILL FLOAT AND CAN BE
REIGNITED ON SURFACE OF WATER.
Fire Fighting Procedures:MATERIAL WILL NOT BURN UNLESS PREHEATED. DO
NOT ENTER CONFINED FIRE SPACE WITHOUT FULL BUNKER GEAR (HELMET WITH
FACE SHIELD, BUNKER COATS, GLOVES AND RUBBER BOOTS). INCLUDING A
POSTIIVE PRESSURE NIOSH APPROVED SELF CONTAINED BREATHING
APPARATUS. COOL FIRE EXPOSED CONTAINERS WITH WATER.
Unusual Fire/Explosion Hazard:NONE IDENTIFIED

Accidental Release

Spill Release Procedures:USE CAUTIOUS JUDGMENT. WEAR RESPIRATOR &
PROTECTIVE CLOTHING AS APPROPRIATE. SHUT OFF SOURCE OF LEAK IF SAFE
TO DO SO. DIKE & CONTAIN. REMOVE WITH VACUUM TRUCKS OR PUMP TO
STORAGE/SALVAGE VESSELS. SOA K UP RESIDUE WITH AN ABSORBENT SUCH AS
CLAY, SAND OR OTHER SUITABLE MATERIAL. DISPOSE OF PROPERLY. FLUSH
ARE WITH WATER TO REMOVE RESIDUE. TAKE UP SMALL SPILLS WITH
ABSORBENT MATERIAL & CLEAN AREA.
Neutralizing Agent:NONE PROVIDED BY MFR

Handling

Handling and Storage Precautions:STORE IN A COOL DRY PLACE WITH
ADEQUATE VENTILATION.
Other Precautions:KEEP AWAY FROM OPEN FLAMES AND HIGH TEMPERATURES.

Exposure Controls

Respiratory Protection:IF EXPOSURE MAY OR DOES EXCEED OCCUPATIONAL
EXPOSURE LIMITS USE A NIOSH-APPROVED RESPIRATOR TO PREVENT
OVEREXPOSURE. IN ACCORD WITH 29 CFR 1910.134 USE EITHER AN
ATMOSPHERE-SUPPLYING RESPIRATOR OR AN AIR-PURIFYING RESPIRATOR FOR
ORGANIC VAPORS AND PARTICULATES.
Ventilation:NONE PROVIDED BY MFR
Protective Gloves:CHEMICAL-RESISTANT GLOVES
Eye Protection:SAFETY GLASSES OR GOGGLES AS APPROPRIATE
Other Protective Equipment:CHEMICAL RESISTANT PROTECTIVE CLOTHING.
Work Hygienic Practices:AVOID SKIN CONTACT. WASH WITH SOAP AND WATER
BEFORE EATING, DRINKING, SMOKING, APPLYING COSTMETICS, OR USING
TOILET FACILITIES. LAUNDER CONTAMINATED CLOTHING BEFORE REUSE.
Supplemental Safety and Health
NONE PROVIDED BY MFR

Chemical Properties

HCC:V6
Boiling Pt:B.P. Text:NOT AVAILABLE
Melt/Freeze Pt:M.P/F.P Text:NOT AVAILABLE
Decomp Temp:Decomp Text:NONE PROVIDED BY MFR
Vapor Pres:NOT AVAILABLE
Vapor Density:NOT AVAILA
Spec Gravity:.99 (H2O=1) APPROX.
pH:NONE PROVIDED
Viscosity:28.0 CST @ 100 DEG F
Evaporation Rate & Reference:NOT AVAILABLE
Solubility in Water:NEGLIGIBLE
Appearance and Odor:CLEAR LIQUID
Percent Volatiles by Volume:NONE PROVIDE
Corrosion Rate:NONE PROVIDED BY MFR

Stability

Stability Indicator/Materials to Avoid:YES
CONTACT WITH STRONG OXIDIZING AGENTS
Stability Condition to Avoid:AVOID HEAT, FLAME
Hazardous Decomposition Products:CARBON MONOXIDE AND OTHER UNIDENTIFIED
ORGANIC COMPOUNDS MAY BE FORMED UPON COMBUSTION.
Conditions to Avoid Polymerization:WILL NOT OCCUR

Disposal

Waste Disposal Methods:PLACE IN AN APPROPRIATE DISPOSAL FACILITY IN
COMPLIANCE WITH LOCAL REGULATIONS. UNDER EPA-CWA, THIS PRODUCT IS
CONSIDERED AN OIL UNDER SECTION 311.

Transport

Transport Information:NOT HAZARDOUS BY DOT REGULATIONS.

Regulatory

SARA Title III Information:THIS PRODUCT IS CLASSIFIED AS A CHRONIC
(DELAYED) HEALTH HAZARD UNDER SECTION 311/312 OF SARA TITLE III.
Federal Regulatory Information:THE COMPONENTS OF THIS PRODUCT ARE
LISTED ON THE EPA/TSCA INVENTORY OF CHEMICAL SUBSTANCES.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.